New Improved RP-HPLC Method for The Estimation of Favipiravir from Solid Dosage Form

 

Gurappa Kashinath Dyade1*, Shyam Pralhad Bothikar2, Bandu Eknath Zarekar3,

Dipali Bhimdevrao Taware4

1Dept of Postgraduate in Pharmaceutical Quality Assurance, SVPM’S College of Pharmacy,

Malegaon (BKII), Baramati Dist Pune - 413115, Maharashtra, India.

2Board of Managemant, Cure Medicines India Pvt Ltd, MIDC Bhosari - 411026, Pune, Maharashtra, India.

3R and D Department, Glenmark Research Centre, Taloja, Navi Mumbai, Maharashtra - 410208, India.

4SVPM’S College of Pharmacy, Malegaon (BKII), Baramati Dist Pune - 413115, Maharashtra, India.

*Corresponding Author E-mail: gkdyade@gmail.com

 

ABSTRACT:

Objective: An improved reverse phase high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for the estimation of Favipiravir from pharmaceutical dosage form. Method: Chromatographic separation was performed on RP-C18 column. The optimized mobile phase (acetonitrile: water of pH 4.8 adjusted with glacial acetic acid) was pumped at a flow rate of 0.8ml/min in the ratio of 35:65% v/ v and the eluent was monitored at 245nm. Results: The assay was performed with tablet dosage form and % of assay was found 101.21% w/w of Favipravir. Linearity was ascertained over the concentration range 1-12µg/ml. The method was statistically validated and found SD; RSD was within acceptable limit, indicated high degree of accuracy and precision of the proposed RP-HPLC method. Conclusion: Due to its simplicity, rapidness, high precision and accuracy the proposed RP-HPLC method can be applied for determination of Favipiravir in routine quality control tests of dosage form.

 

KEYWORDS: Favipiravir, Validation, RP-HPLC, Covid-19, Chromatography.

 

 


INTRODUCTION:

Favipiravir (FPV) chemically 6-Fluoro-3-hydroxy pyrazine-2-carboxamide and pharmacologically favipiravir RTP binds to and inhibits RNA dependent RNA polymerase (RdRp) which ultimately prevents viral transcription and replication1-4. A viral RNA polymerase inhibitor favipiravir is expected to have an effect against a range of influenza viruses. It is reserved for the treatment of novel or remerging influenza1.

 

For estimation of FPV methods such as Visible Spectrophotometric method5, Spectrophotometric method6-8, RP-HPLC method9-12 , Stability indicating HPLC method13, comparative HPLC and UV method14, Stability indicating HPLC-DAD-UV method15,16, forced degradation Stability indicating HPLC method17, potentiometric titration technique18, Green micellar method19, application of reactive dyes20, UPLC-MS/MS method21, Bio analytical technique22-23, triple antiviral therapy24, screening of antiviral agent against covid-1925 and identification of antiviral agent26 have been reported for estimation of FPV alone or in combination with other drugs.

 

The drug is official in recently published Indian Pharmacopoeia3. Chemical structure of drug is shown in (Fig No 1).

 

Fig No 1: Chemical structure of Drug molecule

 

Literature survey revealed that few methods were reported for the estimation of FPV individually or along with other antiviral drug. An attempt has been made to develop more rigid and robust HPLC method for determination of FPV. RP-HPLC methods have been widely used for routine quality control assessment of drugs because of their accuracy, repeatability, selectively, sensitivity and specificity. We have developed a simple, precise, accurate and specific RP-HPLC method for the determination of FPV. Analytical method must be validated before use to ensure that the method under consideration is capable of giving reproducible and reliable results. The proposed RP-HPLC method was validated in accordance with International Conference on Harmonization (ICH) guidelines27,28, by assessing its selectivity, linearity, accuracy, precision, LOD and LOQ.

 

MATERIALS AND METHODS:

Instrumentation:

Analysis was performed with a Shimadzu (Japan) prominence chromatograph equipped with an LC - 20 AT solvent delivery system, a universal loop injector (Rheodyne 7725) of injection capacity of 20µl, and an SPD-20-A UV–Visible detector set at 245nm. The equipment was controlled by a PC work station with clarity software. Compounds were separated on a Phenomenex Luna C18 column (250mm × 4.6mm i d, 5μm particle size) under reversed phase partition conditions. The mobile phase was a 35:65% (v/v) mixture of Acetonitrile: Water (pH 4.8±0.2, adjusted with Acetic acid). The flow rate was set at 0.8ml/min and the run time was 8min. Before analysis both the mobile phase and sample solutions were degassed by the use of a sonicator (Lab man scientific Instruments Chennai) and filtered through a 0.2μm filter (Pall corporation, Mumbai). The identity of the compounds was established by comparing the retention times of compounds in the sample solution with those in standard solutions. Chromatography was performed in an ambient temperature maintained at 40±1°C. The UV spectrum of FPV for selecting the working wavelength of detection was taken using a Shimadzu – 1700 Double beam UV-Visible spectrophotometer (Shimadzu, Kyoto, Japan).

 

Reagents and Chemicals:

Pharmaceutically pure sample of FPV from Glenmark India Ltd was procured as a gift sample and the commercial formulation was purchased from local market. Acetonitrile, water and acetic acid the entire solvents of HPLC grade were obtained from Qualigens India Pvt. Limited, Mumbai, India.

 

Preparation of Stock Solution of FPV:

About 10mg of FPV was accurately weighed and transferred in to 25ml volumetric flasks. The drug was dissolved into mobile phase and the volume was made up to the 25ml with mobile phase. From this standard stock solution, the aliquot of solution was further diluted with mobile phase to obtain standard solution in the conc. range 1 to 12μg/ml.

 

Plot of calibration curve:

Calibration curve was plotted by using standard solutions. All the standard solutions were filtered through syringe filter and injected 20μl solutions each time with Hamilton syringe. The chromatograph was read and the peak areas were measured. Peak areas were then plotted against their respective concentrations. From the calibration curve it was found that drug was linear in the concentration range of 1-12μg/ml. The calibration graph was used as a reference to determine quantitatively conc. of Unknown solution of dosage form.

 

Statistical parameters- Standard regression curve analysis was obtained by use of Microsoft Office Excel software and Means, standard deviations and coefficient of variance were calculated.

 

Assay of tablet formulation: 

Tablets of formulation were triturated into a fine powder form with a glass mortar pestle. Tablet powder equivalent to 25mg of FPV was quantitatively transferred into a 25ml volumetric flask and dissolved in mobile phase and volume was made up to 25ml with mobile phase. The solution was sonicated for 15min, to ensure the uniform and homogenous solution of the drug. Further solution was centrifuged at 500rpm for 10 min and the clear supernatant was collected and filtered through syringe filter (pore size 0.22). The aliquots of clear solution were further diluted to 10ml with mobile phase to obtain tablet solution. Sample solution 20μl with Hamilton syringe was injected and the peak areas were measured for the determination of FPV in tablet formulation.

Method Validation:

The objective of method validation is to demonstrate that the method is suitable for its intended purpose as it is stated in ICH guidelines. The method was validated for linearity, precision (repeatability and intermediate precision), accuracy, selectivity and specificity. Accuracy was assessed by measuring recovery at three different levels. Precision assessed by measurement of intra and inter day precision. In the intraday study the concentrations of all the drugs were calculated six times on the same day at different time intervals. In the inter day study the concentrations of the drugs were calculated six times on different days. Selectivity and specificity of the method were assessed by injecting solutions containing all the drugs; after chromatography three sharp peaks were obtained for all drugs. LOD and LOQ were measured to evaluate the detection and quantitation limits of the method and to determine whether these were affected by the presence of impurities. They were calculated by use of the equations LOD = 3.3σ/S and LOQ = 10σ/S, where σ is the standard deviation of the response and S is the slope of the calibration plot.

 

RESULTS AND DISCUSSION:

HPLC Method Development and Optimization:

This work was focused on optimization of the conditions for the simple and rapid as well as low cost effective analysis including a selection of the proper column and mobile phase to obtain satisfactory results. Many literatures have elaborate discussion on optimization of mobile phase29.

 

Solvent type, solvent strength (volume fraction of organic solvent(s) in the mobile phase and pH of the solution), detection wavelength, and flow rate were varied to determine the chromatographic conditions giving the best separation. The mobile phase conditions were optimized so there was no interference from solvent and excipients. Other criteria, for example time required for analysis, appropriate k range (1 < k < 10) for eluted peaks, assay sensitivity, solvent noise, and use of the same solvent system for extraction of the drugs from the formulations during drug analysis were also considered.

 

To optimize mobile phase, chromatogram of this drug was obtained in mobile phase acetonitrile: water in 60: 40% v/v, but drug was eluted after 9min. Then the proportion of water was increased to 65 % and result was elution of drug within 6min was found. Also mobile phase composition was changed to methanol: water in proportion 70:30% v/v, the result was distorted signals that were not well defined. Addition of 0.5mL acetic acid for adjustment of the pH resulted in good separation and symmetrical peaks.

 

 

To determine the appropriate wavelength for determination of FPV solution of this compound in mobile phase was scanned in the range of 400–200nm. From the UV spectra, suitable wavelength considered for monitoring the drug was 245nm. Solutions of each substance in the mobile phase were also injected directly for HPLC analysis and the responses (peak area) were recorded at 245nm. It was observed that analyte absorbed well at 245nm, and at this wavelength there was no interference from the mobile phase or baseline disturbance, and it was therefore, concluded that 245nm was the most appropriate wavelength for analysis of drug with suitable sensitivity.

 

The optimum mobile phase was, therefore, Acetonitrile: water (pH 4.8±0.1) in the ratio 35:65(v/v). Under this experimental condition sharp peak was obtained at the retention time 5.934min. The optimized chromatogram was obtained and shown in (fig No 2) with the resolution being 5.694.

 

Fig No 2: Optimized chromatogram of Favipiravir

 

Method validation,

The system suitability parameters like capacity factor, number of theoretical plates, and tailing factor for all the analytes were found within the limit, indicating the suitability of the system (Table 1). The values obtained for k′ (1<k′<10) and RS(>2) showed the chromatographic condition was appropriate for separation and quantification of compound. The number of theoretical plates and the tailing factor were within the acceptance criteria of >2000 and ≤1.5, respectively, indicating good column efficiency and optimum mobile phase composition.

 

Table 1: System suitability study results of FPV

Parameters

Favipiravir

Retention time*

5.903

Tailing factor*

0.138

Asymmetrical factor*

0.128

Number of Theoretical plates

11882

Resolution

5.694

Flow rate ml/min

0.8 ml/min

Mobile phase Acetonitrile: Water

35:65 % (v/v)

*Mean of six determinations

 

 

Linearity:

Linearity was tested in the concentration range 1-12μg/ml for FPV overlain chromatograph is shown in (Fig No 3). The solution was chromatographed and obtained results are validated in accordance with the International Conference on Harmonization. The correlation coefficient and intercept (Fig No 4), calculated in the corresponding statistical study (ANOVA; Z), correlation coefficient r2 values > 0.999 and intercepts very close to zero confirmed the good linearity of the method. The Z values calculated for the calibration plots were obtained in satisfactory range, indicating the variances were not significantly different (Table 2).

 

 

Fig No 3: Overlain Chromatograph obtained in linearity study

 

 

Fig No 4: Calibration curve of Favipiravir

 

 

Table 2: Linearity data results of FPV

Parameters

Result

Detection wavelength

245 nm

Beer’s law limit (μg/ml)

2-12

Correlation coefficient (r)

0.9995

Regression equation (y = mx+c)

Y=11.043X+0.3909

LOD (μg/mL)

0.0084

LOQ (μg/mL)

0.5472

 

 

 

Assay:

The percentage label claim of tablet formulation was found to 101.21%. The chromatogram of the analysis of formulation was shown in (Figure 5). Precision of the method was confirmed by the repeated analysis of formulation for six times. The %COV values were found to be. The low %COV values indicated that drug showed good agreement with the label claim ensures the precision of the method shown in (Table No 3).

 

Fig No 5:  Chromatogram of formulation of FPV

 

Table 3: Results of tablet formulations assay

Formulation

Fabiflu 400 mg

Drug

Favipiravir

Label claim (mg/ tablet)

400 mg

Amount found (mg) n = 6

404.84 mg

Drug Content (%)

101.21

Std. Deviation

3.2189

Relative Std Dev (%)

3.1802

 

Precision:

Intraday and Inter day precision was determined by repeating analysis six times on same day for intraday and on next day for inter day precision. The intraday precision was studied with standard deviation as   for tabulated in (Table No 4). The inter day precision was also studied with standard deviation

 

Accuracy,

To check the accuracy of the developed methods and to study the interference of formulation excipients, analytical recovery experiments were carried out as per ICH guidelines.

 

The results of the recovery studies (Figure 6) and its statistical validation data given in (Table No 4) indicate high accuracy of the proposed method. The percentage recovery was found to be in the range of % the %COV values were found to be respectively. (Table No 4).


 

Table 4: Results of Intraday, Inter day precision and recovery analysis of the method

S. No

Parameter

Level of study

Data Title

Obtd. Data

S.D.

 RSD

1

Precision study of FPV

Intraday Precision

Mean of Abs n= 6

102.36

1.9135

1.8694

2

Accuracy study of FPV

80 %

% Purity

101.11

1.2962

1.2844

100 %

100.86

0.8228

0.8158

120 %

98.11

0.7.131

0..7175

S.D.- Standard deviation; COV-coefficient of variance

 


Fig No 6:  Chromatogram of Accuracy 100% study of FPV

 

Robustness:

As defined by the ICH, the robustness of an analytical procedure describes to its capability to remain unaffected by small and deliberate variations in method parameters. Robustness was performed by small variation in the chromatographic conditions and found to be unaffected by small variations like ±2% variation in volume of mobile phase composition, ±0.1ml/min variation in flow rate of mobile phase and ±0.1 variation in pH.

 

Specificity:

The specificity of the HPLC method was ascertained by analyzing standard drug and sample solutions. The retention time of drug was confirmed by comparing the retention time with that of the standard.

 

CONCLUSIONS:

A simple isocratic RP-HPLC method equipped with UV detection has been developed for determination of FPV. The method was validated for accuracy, precision, specificity, and linearity. The run time was relatively short (8 min), which enables rapid quantification of many samples in routine and quality control analysis of tablets. Thus the proposed method is rapid, selective, requires a simple sample preparation procedure, Moreover, the lower solvent consumption leads to a cost effective and represents a good procedure of FPV determination in bulk and in pharmaceutical dosage forms.

 

ACKNOWLEDGEMENTS:

The authors are thankful to Management, Principal SVPM’S College of Pharmacy, Malegaon (BKII) Tal-Baramati Dist-Pune Maharashtra, India for providing the necessary facilities to carry out the research work. Authors are also thankful to Glenmark Pharma Ltd, Taloja Dist. Raigad Maharashtra for supplying the gift sample of Favipiravir.

 

CONFLICTS OF INTEREST:

The authors declared that they have no conflicts of interest.

 

REFERENCES:

1.      Alison Brayfield. Martindale (The Complete Drug Reference). 39th ed. Pharmaceutical Press London UK. 2017(A). PP. A 1002.

2.      Drug Today. Ready Reckoner of Current Medical Formulations. Vol 28. No 4. April July 2022 Vol No 1. 380

3.      Indian Pharmacopoeia, Govt. of India, Ministry of Health and Family Welfare, The Indian Pharmacopoeia Commission Ghaziabad. 8th ed (Addendum). 2021; pp.4567, 4650.

4.      Mayur S. Jain, Shashikant D. Barhate. Favipiravir has been investigated for the treatment of life-threatening pathogens such as Ebola virus, Lassa virus, and now COVID-19: A Review. Asian Journal of Pharmaceutical Research. 2001: 11(1); 39-42. 10.5958/2231-5691.2021.00008.3

5.      Panchale W.A., Bisen S.B., Manwar J.V., Bakal R.L., Tidke T.V., Paithankar M.N., Vakhare A.G., Development of visible spectrophotometric methods for the analysis of favipiravir in pure drug and tablet formulation. GSC Biological and Pharmaceutical Sciences. 2022; 20(2); 184-195.

6.      Devulapally Shravya, Jorige Archana. A New Validated UV Spectroscopic Method for the Estimation of Favipiravir, an anti-influenza drug in COVID 19. Asian Journal of Pharmaceutical Analysis. 2024; 14(2):65-8.

7.      Jeevan J.B., Venkata K.R. Ultraviolet Spectrophotometric method development for estimation of new antiviral repurposing drug Favipiravir. Asian Journal of Pharmaceutical and Clinical Research, 2021; 14(7); 67-69.

8.      Rele Rajan V., Tiwatane Prathamesh P. Simple Extractive Spectrophotometric Method for Determination of Favipiravir from Pharmaceutical Formulation. Asian Journal of Research in Chemistry. 2022; 15(4): 299-2.

9.      Tapkir A.S. Ghune V.B., Method development and validation of Favipiravir by RP-HPLC. Innovative Journal of Medical Science, 2022; 6(2); 13-19.

10.   Aydinoglu S., Bozyel M., Favipiravir determination in pharmaceutical formulation via HPLC chromatographic Approach. Iranian Journal of Chemistry and Chemical Engineering. 2022; doi:10.30492/ijcce.2022.547653.5147.

11.   Kalshetti M.S., Adlinge S.G. Development and Validation of HPLC Method for Qualification of Favipiravir in Tablet. Research Journal of Pharmacy and Technology. 2022; 15(3); 1319-1322.

12.   Bulduk I. HPLC-UV method for qualification of favipiravir in pharmaceutical formulations. Acta Chromatographica. 2021; 33(3); 209-215.

13.   Lingabathula S., Jain N., Stability-indicative and cost-effective analytical method development and validation of favipiravir and peramivir in bulk and pharmaceutical dosage form by using RP-HPLC. International Journal of Applied Pharmaceutics. 2021; 13(4); 265-271. 

14.   Bulduk I., Comparison of HPLC-UV Spectrophotometric Methods for Qualification of Favipiravir in Pharmaceutical Formulations. Iranian Journal of Pharmaceutical Research. 2021; 20(3); 57.

15.   Marzouk H.M., Rezk M.R., Gouda A.S., Abdel-Megied A.M., A novel stability-indicating HPLC-DAD method for determination of favipiravir, a potential antiviral drug for COVID-19 treatment; application to degradation kinetic studies and in-vitro dissolution profiling. Microchemical Journal. 2022; 172; 106917.

16.   N S Yamani, Mukthinuthalapati Mathrusri Annapurna. Stability Indicating RP-HPLC Method for the estimation of Favipiravir in API and Pharmaceutical Dosage Forms (Tablets). Research Journal of Pharmacy and Technology. 2022; 15(12):5700.6

17.   Sayyed N.S.A., Lajporiya M., Manjra M., Patel S., Aejaz A.G., Khan G.J., Analytical method development and validation and forced degradation stability-indicating studies of favipiravir by RP-HPLC and UV in bulk and pharmaceutical dosage form. Journal of Pharmaceutical Research International. 2021; 33(48B); 254-271.

18.   Rele Rajan V, Tiwatane Prathamesh P. A Validated Potentiometric Titration Method for Quantitative Determination of Favipiravir from Pharmaceutical Preparation. Asian Journal of Research in Chemistry. 2022; 15(1):49-1.

19.   Sharaf Y.A., Deeb S.E., Ibrahim A.E., Al-Harrasi A., Sayed R.A., Two green micellar HPLC and mathematically assisted UV spectroscopic methods for simultaneous determination of molnupiravir and favipiravir as a novel combined COVID-19 antiviral regimen. Molecules. 2022; 27(7); 2330.

20.   Rele Rajan V., Tiwatane Prathamesh P. Application of reactive dyes in Validation of favipiravir from pharmaceutical dosages. Asian Journal of Research in Chemistry. 2023; 16(1):27-30.

21.   Rezk M.R., Badr K.A., Abdel-Naby N.S., Ayyad M.M., A novel, rapid and simple UPLC-MS/MS method for qualification of favipiravir in human plasma: Application to a bioequivalence study. Biomedical Chromatography. 2021; 35(7); e5098. https://doi.org/10.1002/bmc.5098.

22.   Abdallah I.A., Hammad S.F., Bedair A., Elshafeey A.H., Mansour F.R., Determination of favipiravir in human plasma using homogeneous liquid-liquid micro extraction followed by HPLC/UV. Bioanalysis. 2021; 14(4); 205-216.

23.   Duse P.V., Baheti K.G., Bioanalytical Method Development and Validation for the Determination of Favipiravir in Spiked Human Plasma by using RP-HPLC. Journal of Pharmaceutical Research International. 2021; 33(47A); 275-281.

24.   Kaur Simaranjit, Kaur Kuldeep, Kaur Herbaksh. Triple Combination Antiviral Therapy. Research J. Pharm. and Tech. 2014; 7(10): 1190-1192.

25.   Deshmukh Nitin, Soni Love Kumar. Prediction of In-silico ADMET Properties and Molecular docking study of Substituted Thiadiazole for screening of Antiviral activity against protein target Covid-19 main protease. Research Journal of Pharmacy and Technology. 2023; 16(12):5802-7.

26.   Ruby Singh, K. Pani Prasad, Anshul Tiwari, Ajey Pathak, Prachi Srivastava. Molecular docking and Simulation study to identify Antiviral agent by targeting MX protein against Betanodavirus causing viral nervous necrosis in Barramundi. Research J. Pharm. and Tech. 2021; 14(3):1405-1411.

27.   International Conference on Harmonization (ICH), Q2A:Text on Validation of Analytical Procedures:  Definitions and Terminology. Vol. 60, US FDA Federal Register, 1995

28.   International Conference on Harmonization (ICH), Q2B: Validation of Analytical Procedures:   Methodology. Vol. 62, US FDA Federal Register, 1997.

29.   Dyade G. K., Sawant R. L., Joshi H. A., Shinde A. D., Bandal R. S., Gadhingleskar S. V. A Novel Approach: Effect of polarity Index of mobile phase on Retention Time of Antihyperlipidemic Antihypertensive and Angiotensin inhibiting Drugs in RP-HPLC Method. Research J. Pharm. and Tech. 2020; 13(7): 3065-3071.

 

 

 

Received on 28.04.2026      Revised on 25.06.2026

Accepted on 07.08.2026      Published on 12.10.2026

Available online from October 21, 2026

Asian Journal of Pharmaceutical Analysis. 2026; 16(4):259-264.

DOI: 10.52711/2231-5675.2026.00040

©Asian Pharma Press All Right Reserved

 

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License. Creative Commons License.